Top 15 Turbidity Meters

 

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter Set of 6

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter (Set of 6)

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter (Set of 6) - Can be used for standards or water samples. 10ml volume capacity. Set of six glass test tubes with screw-on caps for use with lamotte 2020e turbidity meter and smart 3 colorimeter (meters not included). White line ensures test tube is correctly aligned in the meter.

 

Portable Turbidity Meter High Accuracy 230V - HI98703-02 - EACH

Portable Turbidity Meter, High Accuracy, 230V – HI98703-02 – EACH

Portable Turbidity Meter, High Accuracy, 230V – HI98703-02 – EACH - Package contents, 1 × liumy ph meter, 1 × user manual, 1 x 24-month warranty, 24 hours of customer service. Ease of use, you just remove the protective cap and immerse the ph meter electrode in the solution and turn on the ph by “on / off” switch to be measured beats the heck out of trying to see the colors of a litmus strip. Wide use, it’s great for home and laboratory uses water, pools, aquariums, spas, hydroponics, food, wine and beer making and more. Fast and reliable reading, highly accurate for measuring range of 0-14 ph, 01 ph resolution, measure & display ph result simultaneously with lcd display, reliable and quick reading. Hanna instruments inc.

 

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter ISO 115V 001 01 1 FNU Resolution

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter, ISO, 115V, 0.01; 0.1; 1 FNU Resolution

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter, ISO, 115V, 0.01; 0.1; 1 FNU Resolution - 99 10. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected. 0 to 99. Accuracy at25 degree c fnu mode- +/-2 percent of reading plus stray light, fau mode- +/-10 percent of reading, ntu ratio mode- +/-2 percent of reading plus stray light/+/-5 percent of reading above 1000 ntu, ntu non-ratio mode- +/-2 percent of reading plus stray light. Comprehensive contextual help is available at a simple key press. Data can be transferred to a pc via optional hi 920013 usb cable and hi 92000 windows compatible software. The hi 88713 turbidity bench meter has complete glp (good laboratory practice) functions that allow traceability of the calibration conditions. 00 to 9. 01 0. 99 10. 1 1 fau, ntu ratio mode- 0. 0 to 99. 1 1 fnu, fau mode- 0. 9 100 to 1000 fnu, fau mode- 10. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process. 0 to 99. Calibration points can be modified when user prepared standards are used. 1 1 ntu/0. 9 100 to 245 ebc. 00 to 9. 00 to 9. 0 to 99. 9 100 to 980 ebc, ntu non-ratio mode- 0. Hi 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. Resolution fnu mode- 0. 9 100 to 1000 ntu 0. 01 0. 0 to 99. 1 1 ebc. 9 100 to 4000 ntu 0. 99 10. 9 100 to 4000 fau, ntu ratio mode- 0. A two, three, four or five-point calibration can be performed using the supplied standards. 01 0. 00 to 9. 00 to 9. 1 1 ebc, ntu non-ratio mode- 0. It also compensates for variations in intensity of the led, limiting the need for frequent calibration. 1 1 ntu/0. 01 0. The hi 88713 turbidity bench meter meets and exceeds the requirements of the iso 7027 standard. 0 to 99. 01 0. 99 10. Range fnu mode- 0. The hi 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic lcd. Up to 200 measurements can be stored in internal memory. 99 10.

 

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette 000 to 5000 FTU 001 FTU Resolution -05 FTU Accuracy

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette, 0.00 to 50.00 FTU, 0.01 FTU Resolution, +/-0.5 FTU Accuracy

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette, 0.00 to 50.00 FTU, 0.01 FTU Resolution, +/-0.5 FTU Accuracy - 01 ftu (0. 00 ftu) 1 ftu (50 to 1000 ftu) resolution. Both versions meet the requirements of glp (good laboratory practice) protocols for last calibration data storage. 00 to 50. Hanna instruments uses the primary standard amco-aepa-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. Ftu is equivalent to the other internationally recognized unit ntu (nephelometric turbidity unit). 00 to 50. Hanna instruments has chosen 10 ftu as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. Hi 93703 can be used with both standards. Hanna amco-aepa-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. 00 ftu 50 to 1000 ftu range. +/-0. Hi 93703 has been designed according to the iso 7027 international standard, consequently the turbidity unit is the ftu (formazine turbidity unit). The hi 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and pc compatibility via the rs232 interface and windows compatible hi 92000 software. Microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements. Silicon photocell light detection. 3 points (0 ftu, 10 ftu and 500 ftu) calibration. Infrared ledlight source. It is easy to calibrate (with 3 point calibration) using amco-epa standards and is iso 7027 compliant. It is is supplied complete with glass cuvette, batteries and instructions. 5 ftu or +/-5 percent of reading (whichever is greater) accuracy. Measures 8-11/16″ length by 3-3/16″ width by 2-19/32″ height.

 

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set For Turbidity Meter

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set, For Turbidity Meter

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set, For Turbidity Meter - The 25 mm round cuvets made from special optical glass guarantee the repeatability and consistency of the measurements. The cuvets should be periodically washed with acid. Any cuvet with visible scratches will be discarded. Always handle the cuvet by touching only the cap or its top side (over the horizontal line). The cuvets should be free of scratches or cracks.

 

Hanna Instruments HI88703-11 Turbidity Calibration Standards Kit For HI88703 Benchtop Turbidity Meter

Hanna Instruments HI88703-11 Turbidity Calibration Standards Kit, For HI88703 Benchtop Turbidity Meter

Hanna Instruments HI88703-11 Turbidity Calibration Standards Kit, For HI88703 Benchtop Turbidity Meter - Includes . Used with hanna instruments hi 88703 benchtop turbidity meter (sold separately). Primary standards for calibration of a turbidity meter.

 

Milwaukee Mi415 Turbidity Meter 000 - 5000 FNU50 - 1000 FNU 0011 FNU Resolution

Milwaukee Mi415 Turbidity Meter, 0.00 – 50.00 FNU/50 – 1000 FNU, 0.01/1 FNU Resolution

Milwaukee Mi415 Turbidity Meter, 0.00 – 50.00 FNU/50 – 1000 FNU, 0.01/1 FNU Resolution - 00 fnu/50, 1000 fnu, 0. 00, 50. 01/1 fnu resolution offers accurate and reliable readings. Milwaukee mi415 turbidity meter, 0.

 

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit - 7 x 3. The device operates on four 1. 5v aa batteries hi 93703-0 & hi 93703-10 cal. Hanna instruments holds many firsts in the field of analytical instrumentation, including a ph electrode with a built-in temperature sensor, an electronic pocket-sized ph tester, and a replaceable electrode ph pocket tester. 00 to 50. 00 formazine turbidity unit (ftu) and 50 to 1000 ftu, + or -. 5 ftu or 5% of reading, with a typical emc deviation of + or – 2% fs. Founded in 1978, hanna is headquartered in woonsocket, ri, with subsidiaries in 32 countries. 5v aa batteries. What’s in the box two glass cuvettes with caps four 1. The hanna instruments hi 93703c is a portable microprocessor-based turbidity meter. Turbidity meters measure the loss of transparency due to suspended particles present in a solution. To assure the quality of its products, hanna is a vertically integrated manufacturer and does not subcontract any part of its manufacturing. 6″), with weight 510 g (1. Hanna instruments manufactures a wide variety of analytical instrumentation, including ph meters, multi-parameter meters, electrodes, chemical reagents, and buffer solutions. Solutions hi 93703-50 cleaning solution tissue for wiping cuvettes carrying case instructions. ). Turbidity range is 0. They are commonly used to measure the turbidity of water in both the field and laboratory. The meter has 3-point calibration (0, 10, and 500 ftu), uses an infrared led as a light source, and automatically shuts off after five minutes of non-use. 2 x 2. 1 lb. Dimensions are 220 x 82 x 66 mm (8.

 

WTW 600544 Cal KalStd P Turbidity Meter 10000NTU IR

WTW 600544 Cal. Kal.Std P Turbidity Meter, 10000NTU IR

WTW 600544 Cal. Kal.Std P Turbidity Meter, 10000NTU IR - For ratiometric measurements, there is no specific standard method to be followed rather, procedures are established by the application or industry. Therefore, lab meters for high values are equipped with several measuring options ratio modes calculate the final result from different measured angles. The ir measurement is required by din iso, the white light measuring by us epa. The reduction of light intensity in this case leads to a more accurate result than a 90° nephelometric measurement. White light has a higher sensitivity for small particles, however, the inherent coloration of the solution has a stronger disturbing effect in this case. Nephelometric or transmittance measuring-the nephelometric measurement at 90° scattered light is advantageous for lower turbidity, whereas the transmission measurement at 180° is beneficial for medium to high turbidity values with increasing turbidity, restray and scattering effects between particles are growing bigger.

 

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale 0 Degree C to 50 Degree C Temperature Range 52 mm Height 104 mm Width 192 mm Length

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale, 0 Degree C to 50 Degree C Temperature Range, 52 mm Height, 104 mm Width, 192 mm Length

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale, 0 Degree C to 50 Degree C Temperature Range, 52 mm Height, 104 mm Width, 192 mm Length - Turbidity refers to the concentration of undissolved, suspended particles present in a liquid. By measuring turbidity, by photometric or tube methods, it is possible to estimate suspended solids content. Mi415 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9v battery and instructions. Turbidity measurement is achieved by analyzing the amount of light refracted from suspended particles such as clay, silt and organic material. 00 fnu, and 50 to 1000 fnu that can accommodate the most turbid condition you may encounter. 00 to 50. For potable water applications turbidity is a good indicator of water quality. Turbidity is a measure of the clarity of a sample. Mi415 has two operating ranges 0.

 

Extech TB400 Portable Turbidity Meter

Extech TB400 Portable Turbidity Meter

Extech TB400 Portable Turbidity Meter - Microprocessor-based circuitry assures high accuracy and repeatable readings. Requires only a 10ml sample size. Portable design allows you to take measurement on-site instead of bringing solution back to the lab. Measures up to 1000 ntu (nephelometric turbidity unit) with 001 ntu resolution. Large big-digit lcd and splash-proof front panel.

 

Scientific TDS Meter Measures Turbidity 0-9990ppm Temperature 0-99C32-212F Electrical Conductivity 0-4999uS Accurate to within - 2 Comes with Protective Leather Case

Scientific TDS Meter: Measures Turbidity (0-9990ppm), Temperature (0-99C/32-212F), Electrical Conductivity (0-4999uS). Accurate, to within +/- 2%. Comes with Protective Leather Case

Scientific TDS Meter: Measures Turbidity (0-9990ppm), Temperature (0-99C/32-212F), Electrical Conductivity (0-4999uS). Accurate, to within +/- 2%. Comes with Protective Leather Case - Measures electrical conductivity 0-4999 µs (+/- 2% accuracy). Measures tds 0-9990 ppm (+/-2% accuracy). Comes with a protective leather case. Easy to read backlight turns green if water is clear (tds40ppm). Measures temperature 0-99 c / 32-212 f (+/- 3% accuracy).

 

HF Scientific AO-99543-20 Microtpw Handheld Turbidity Meter EPA Compliant

HF Scientific AO-99543-20 Microtpw Handheld Turbidity Meter, EPA Compliant

HF Scientific AO-99543-20 Microtpw Handheld Turbidity Meter, EPA Compliant - Lab equipment & instruments. Hf scientific microtpw handheld turbidity meter, epa compliant. Hf scientific brand products. Manufactured by cole-parmer.

 

Oakton T-100 Turbidity Meter handheld waterproof with standards

Oakton T-100 Turbidity Meter, handheld, waterproof, with standards

Oakton T-100 Turbidity Meter, handheld, waterproof, with standards - What’s included three sample cuvettes, a light shield cap, 10-ml silicone oil, lint-free cloth, 4 aaa batteries, and hard carrying case. The oakton t-100 turbidity meter is easy to calibrate, meter automatically prompts you to the next calibration standard. 0, 100 and 800 ntp) in hpte bottles, with four label led cuvettes for standards. Sealed optical system with infrared light source delivers high accuracy across entire range. Power saving function lets you take over 1000 readings on a single set of aaa batteries. The large custom lcd displays reading and units of measure. Waterproof and dustproof with ip67-rated housing that floats meets performance criteria as specified by iso 7027 (din en 27027) method compliant with astm d6855-03 (epa recognized) four point push-button calibration for full-range accuracy auto-ranging from 0 to 1000 ntp. Meter also includes 60-ml of four primary standards (0. Other features include auto-off, diagnostic error messages, and auto-ranging function. 02, 20.

 

Hanna Instruments HI731331N Spare Cuvette For Turbidity Meter Pack of 4

Hanna Instruments HI731331N Spare Cuvette, For Turbidity Meter (Pack of 4)

Hanna Instruments HI731331N Spare Cuvette, For Turbidity Meter (Pack of 4) - Turbidity is the cloudiness of a liquid caused by the presence of suspended solids (particles) that may include microorganisms, yeast, or sediment. Turbidity meters are commonly used to test drinking water, environmental water, and water used for food and beverages for compliance with government standards. It is an accessory for use with the hanna instruments hi 98703 portable turbidity meter, which is used to test drinking water and ambient water to meet government standards, and to monitor water used in the manufacture of food and beverages. Turbidity meters (also called turbidimeters) determine the concentration of solids in a sample of liquid (usually water). The company, founded in 1978 and headquartered in woonsocket, ri, meets international organization for standardization (iso) standard 9001. The hanna instruments hi 731331n spare cuvette is made of glass. Hanna instruments manufactures analytical instrumentation and supplies, including ph meters, electrodes, chemical reagents, and buffer solutions. Turbidity meters indirectly determine the concentration of these solids by measuring the light scattered by particles in the sample.





We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.