Best 16 Reference Electrodes

 

Gamry 930-00015 Silver Chloride Reference Electrode

Gamry 930-00015 Silver Chloride Reference Electrode

Gamry 930-00015 Silver Chloride Reference Electrode - It provides a stable reference point for electrochemical experiments. The silver/silver chloride reference electrode is a good alternative to the saturated calomel electrode.

 

Hach B20B300 Radiometer Analytical XR300 Reference Electrode AgAgCl reference screw cap

Hach B20B300 Radiometer Analytical XR300 Reference Electrode (Ag/AgCl reference, screw cap)

Hach B20B300 Radiometer Analytical XR300 Reference Electrode (Ag/AgCl reference, screw cap) - Hach’s innovative menu designs and simple keypads are made for easy use. The truly intuitive design allows you to skip studying complicated user manuals and spend time measuring. Many electrodes work specifically to deliver accurate results and the quickest response, even in challenging environments. You don’t need an answer, but the right one, and fast. These reliable, high-performance systems move easily from the benchtop directly to the testing site. Optimized stabilization algorithms in hach meter platforms eliminate operator guesswork and reduce inaccurate measurements. Hach’s probes and non-glass electrodes, the industry’s toughest, are waterproof and designed to withstand the rigors of outdoor testing and frequent use.

 

Hach 9316900 Replaceable Reference Electrode for H130 H135 H138 miniLab Models

Hach 9316900 Replaceable Reference Electrode for H130, H135 & H138 miniLab Models

Hach 9316900 Replaceable Reference Electrode for H130, H135 & H138 miniLab Models - Parameter electrode. Platform replacement reference for h130, h135 & h138 minilab models.

 

Orion pH Electrode Filling Solution for Reference Electrode and Inner Chamber Box of 5

Orion pH Electrode Filling Solution for Reference Electrode and Inner Chamber (Box of 5)

Orion pH Electrode Filling Solution for Reference Electrode and Inner Chamber (Box of 5) - For 4215f60 half cell reference electrode use 4215f70. Requires 4215f60 reference electrode uses 4210s21 replacement membrane modules (1 included) and 4215f70 filling solution.

 

NEW THERMO SCIENTIFIC 214672-A01 100058 ORION REFERENCE ELECTRODE D541678

NEW THERMO SCIENTIFIC 214672-A01 100058 ORION REFERENCE ELECTRODE D541678

NEW THERMO SCIENTIFIC 214672-A01 100058 ORION REFERENCE ELECTRODE D541678 - New thermo scientific 214672-a01 100058 orion reference electrode d541678.

 

eDAQ Inc ET069 Leakless AgAgCl Reference Electrode

eDAQ, Inc. ET069 Leakless Ag/AgCl Reference Electrode

eDAQ, Inc. ET069 Leakless Ag/AgCl Reference Electrode - An all plastic leakless ag/agcl reference electrode suitable for electrochemistry research and teaching. The et069 electrode is completely leakless and will not contaminate your sample with chloride or silver ions. The electrode can be used with most solvents including alcohols, ketones, esters, and halogenated hydrocarbons, as well as tetrahydrofuran (thf), dimethylsulfoxide (dmso), acetonitrile, and dichloromethane, making it suitable for most cyclic voltammetry experiments.

 

eDAQ Inc ET072 Leakless Miniature AgAgCl Reference Electrode

eDAQ, Inc. ET072 Leakless Miniature Ag/AgCl Reference Electrode

eDAQ, Inc. ET072 Leakless Miniature Ag/AgCl Reference Electrode - The et072 electrode is completely leakless and will not contaminate your sample with chloride or silver ions. The electrode can be used with most solvents including alcohols, ketones, esters, and halogenated hydrocarbons, as well as tetrahydrofuran (thf), dimethylsulfoxide (dmso), acetonitrile, and dichloromethane, making is suitable for most cyclic voltammetry experiments. A plastic body, ag/agcl reference electrode suitable for electrochemistry research and teaching.

 

Sensorex SG201CIT Glass Body Calomel Free pH and Reference Electrode Triple Junction Re-fillable Reference 12mm Diameter 150mm Length

Sensorex SG201CIT Glass Body Calomel Free pH and Reference Electrode, Triple Junction, Re-fillable Reference, 12mm Diameter, 150mm Length

Sensorex SG201CIT Glass Body Calomel Free pH and Reference Electrode, Triple Junction, Re-fillable Reference, 12mm Diameter, 150mm Length - The “calomel free” design features an ag/agcl based double unction eference with a unique silver ion trap acting as a third junction to impede any silver ion contact with the sample. The performance of a calomel electrode is now available without the hazardous mercury associated with the design. Reference output is adjusted to deliver the same output as a calomel lectrode using a silver chloride reference.

 

Sensorex S201CIT Epoxy Body Calomel Free pH and Reference Electrode Triple Junction Re-fillable Reference 12mm Diameter 150mm Length

Sensorex S201CIT Epoxy Body Calomel Free pH and Reference Electrode, Triple Junction, Re-fillable Reference, 12mm Diameter, 150mm Length

Sensorex S201CIT Epoxy Body Calomel Free pH and Reference Electrode, Triple Junction, Re-fillable Reference, 12mm Diameter, 150mm Length - The performance of a calomel electrode is now available without the hazardous mercury associated with the design. The “calomel free” design features an ag/agcl based double unction eference with a unique silver ion trap acting as a third junction to impede any silver ion contact with the sample. Reference output is adjusted to deliver the same output as a calomel lectrode using a silver chloride reference.

 

eDAQ Inc ET070 Hydroflex - Hydrogen Reference Electrode

eDAQ, Inc. ET070 Hydroflex – Hydrogen Reference Electrode

eDAQ, Inc. ET070 Hydroflex – Hydrogen Reference Electrode - You can use the hydroflex electrode to calibrate your everyday ag/agcl or calomel electrodes, or use it as the reference electrode in situations where other electrodes might not be suitable. For example, hydroflex is particularly suitable as a reference electrode in aqueous acid or alkali solutions, and can be used at pressures up to 10 bar and temperatures of up to 210°c. The hydroflex electrode has an internal, replaceable, cartridge that continuously generates a low volume hydrogen flow that passes through a platinized gas diffusion electrode, resulting in a compact reference electrode without the need for a separate hydrogen source.

 

Hanna Instruments HI5313 PEI AgAgCl Reference Electrode For Fluoride ISE 4mm Banana Connection

Hanna Instruments HI5313 PEI Ag/AgCl Reference Electrode, For Fluoride ISE, 4mm Banana Connection

Hanna Instruments HI5313 PEI Ag/AgCl Reference Electrode, For Fluoride ISE, 4mm Banana Connection - Electrode is 12mm in diameter and 120mm long, and has a 1m cable with a banana jack connector for attaching to compatible meters. Ceramic junction for durability. Ag/agcl single-junction reference for general applications. Pei body resists solvents and is sealed for minimal maintenance. Half-cell reference electrode for use with half-cell fluoride ises.

 

Hanna Instruments HI5311 Glass AgAgCl Reference Electrode For General Purpose and Titration 4mm Banana Connection

Hanna Instruments HI5311 Glass Ag/AgCl Reference Electrode, For General Purpose and Titration, 4mm Banana Connection

Hanna Instruments HI5311 Glass Ag/AgCl Reference Electrode, For General Purpose and Titration, 4mm Banana Connection - Electrode is 12mm in diameter and 120mm long, and has a 1m cable with a banana jack connector for attaching to compatible meters. Half-cell reference electrode for use with half-cell measuring electrodes in titration and other water testing applications. Ag/agcl double-junction reference to protect against silver wire contamination. Glass body withstands corrosive materials and solvents, and is refillable, allowing the filling solution composition to be adjusted to suit the sample requirements. Ceramic junction for durability in demanding applications.

 

Orion Reference Electrode Fill Solution for Sodium ISE with Low Sodium Sample Levels Na 5 x 60ml Volune Bottle

Orion Reference Electrode Fill Solution for Sodium ISE with Low Sodium Sample Levels, Na, 5 x 60ml Volune Bottle

Orion Reference Electrode Fill Solution for Sodium ISE with Low Sodium Sample Levels, Na, 5 x 60ml Volune Bottle - Filling/maintenance solutions for use with your thermo scientific orion ion selective electrodes (ise). Optimum result ise filling solutions are specially designed for the ionplus series ion selective electrodes.

 

Reference Electrode 2060A-10T

Reference Electrode 2060A-10T

Reference Electrode 2060A-10T - Applicable temperature range(c) 0-100. Liquid junction ceramic. Applicable glass electrode 1066a 1076a. Internal solution #300 (kcl). Standard type.

 

Hanna Instruments HI5412 Glass HgHg2Cl2 Reference Electrode For ISE and Titrations 4mm Banana Connection

Hanna Instruments HI5412 Glass Hg/Hg2Cl2 Reference Electrode, For ISE and Titrations, 4mm Banana Connection

Hanna Instruments HI5412 Glass Hg/Hg2Cl2 Reference Electrode, For ISE and Titrations, 4mm Banana Connection - -5 to 30 degree c recommended operating temperature. 1 bar maximum pressure. Ceramic, single / 15-20 micro l/h junction/flow rate. 1m cable. Reference electrode for general purpose, ise and titrations. 4mm banana connection. Kcl 3. 5m electrolyte. Body made of glass. Measures 12mm od by 120mm insertion length. Single, hg/hg2cl2 reference.

 

Cole-Parmer PTFE upper junction for pH reference electrode 05899-25

Cole-Parmer PTFE upper junction for pH reference electrode 05899-25

Cole-Parmer PTFE upper junction for pH reference electrode 05899-25 - Material ptfe, use with 05899-25, description ptfe upper junction for ph reference electrode 05899-25, manufactured by cole-parmer.