25 Coolest Glass Fiber Filters in 2019

 

Whatman 1823-024 Glass Microfiber Binder Free Filter 27 Micron 22 s100mL Flow Rate Grade GFD 24cm Diameter Pack of 100

Whatman 1823-024 Glass Microfiber Binder Free Filter, 2.7 Micron, 2.2 s/100mL Flow Rate, Grade GF/D, 2.4cm Diameter (Pack of 100)

Whatman 1823-024 Glass Microfiber Binder Free Filter, 2.7 Micron, 2.2 s/100mL Flow Rate, Grade GF/D, 2.4cm Diameter (Pack of 100) - Grade gf/d circles 24mm. Glass microfiber filter retention 27µm diameter 24cm. Faster in flow rate and overall filtration speed than cellulose filter. Designed as a membrane prefilter and available in sizes to fit most holders. Will provide good protection for finely retentive membranes.

 

Sterlitech - Grade GC-50 Glass Fiber Filter 05um Pore Size 47 mm Diameter 100pk - GC5047100

Sterlitech – Grade GC-50 Glass Fiber Filter, 0.5um Pore Size, 47 mm Diameter, 100/pk – GC5047100

Sterlitech – Grade GC-50 Glass Fiber Filter, 0.5um Pore Size, 47 mm Diameter, 100/pk – GC5047100 - Fine porosity, medium/slow flow rate, with a 0. 5um size particle retention. 45um or smaller) and suspeded solids anlysis of industrial waters and wastewater. Used as a pre-filter (0. Binderless glass microfiber. This filter is comparable to the grade c or 934-ah.

 

Millipore AP4002405 Glass Fiber Filter without Binder for Prefiltration and Contamination Analysis 07 Micron 6mLmin x sq cm Water Flow Rate AP40 24mm Diameter Pack of 500

Millipore AP4002405 Glass Fiber Filter without Binder for Prefiltration and Contamination Analysis, 0.7 Micron, 6mL/min x sq cm Water Flow Rate, AP40, 24mm Diameter (Pack of 500)

Millipore AP4002405 Glass Fiber Filter without Binder for Prefiltration and Contamination Analysis, 0.7 Micron, 6mL/min x sq cm Water Flow Rate, AP40, 24mm Diameter (Pack of 500) - Grade gf/f circles 47mm. Recommended for standard methods total suspended solids 2540d^recommended for usepa method 1311 for tclp analysis^maintains structural integrity without weight loss when ignited to 550degree c (1022degree f) after sample filtration filter code ap40 pore size (m) 07 thickness (m) 475^recommended for determining volatile suspended matter in wastewater and industrial effluents water flow rate, ml/min x cm squared 6 air resistance mm of h2o at 105 fpm or 53 cm/s 50 air flow liters/min/cm squared at 10 psi 445^dop penetration at 105 fpm (%) 0002 weight (g/m squared) 65 maximum temperature degree c 550. Recommended for dna binding and purification. Very effective in filtering finely precipitated proteins.

 

Sterlitech - 934-AH Borosilicate Glass Fiber Filter 47 mm 100 pk - AH4700

Sterlitech – 934-AH Borosilicate Glass Fiber Filter, 47 mm, 100 pk – AH4700

Sterlitech – 934-AH Borosilicate Glass Fiber Filter, 47 mm, 100 pk – AH4700 - Fine porosity, fast flow rate, with a 1. 5um size particle retention. 2). The 934-ah borosilicate glass fiber filter is the standard for suspended solids content and related measurements (sm 2540d and epa method 160.

 

Thomas B1100 Borosilicate Glass Microfiber Filter 1 Micron Medium-Fast Flow Grade B 11cm Diameter Pack of 100

Thomas B1100 Borosilicate Glass Microfiber Filter, 1 Micron, Medium-Fast Flow, Grade B, 11cm Diameter (Pack of 100)

Thomas B1100 Borosilicate Glass Microfiber Filter, 1 Micron, Medium-Fast Flow, Grade B, 11cm Diameter (Pack of 100) - Fine porosity, medium to fast flow rate, with a 1 micrometer size particle retention. Because of the characteristically high flow rates of depth filters, they are generally used in applications such as single and multi-process removal of sediment and course particulate. Depth filtration categorizes filter media that traps particulate within the random matrix of fibers found within the thickness of the media. Glass micro fiber filters are available without binders, making the inertmatrix an ideal medium to entra-sediment for further analysis and counting. Ideally suited for the collection of biochemical polymers that have been precipitated by denaturation. The efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. Depth filtration glass micro fiber. Binderless borosilicate glass microfiber. This material is twice as thick as grade a with a higher loading capacity. Also, depth filtration media is commonly used as pre-filtration prior to surface filtration substrates such as membranes. May also be used as a solid particulate filter for gasses or as a prefilter. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence of, if any, binder material that acts as a strengthening agent and aids in holding the fibers together. 140 grams per meter squared basis weight.

 

Foxx Life Sciences 36C-9831-FLS EZFlow Membrane Disc Filter Glass Fiber 90 mm Diameter 1 µm Pore Size Pack of 25

Foxx Life Sciences 36C-9831-FLS EZFlow Membrane Disc Filter, Glass Fiber, 90 mm Diameter, 1 µm Pore Size (Pack of 25)

Foxx Life Sciences 36C-9831-FLS EZFlow Membrane Disc Filter, Glass Fiber, 90 mm Diameter, 1 µm Pore Size (Pack of 25) - These glass fiber disc filters have good solids holding capacity and can be used as pre-filters for heavily contaminated solution samples. 00µm pore size and can be sterilized by autoclaving. Ezflow 90mm glass fiber membrane disc filters are manufactured from borosilicate glass without binders. The glass fiber membrane disc filters have high flow rates, wet strength, and are available in a 1. All materials comply with usp class vi standards.

 

Ahlstrom 1610-0470 Borosilicate Glass Microfiber Filter Paper 11 Micron Medium Flow Grade 161 47cm Diameter Box of 100

Ahlstrom 1610-0470 Borosilicate Glass Microfiber Filter Paper, 1.1 Micron, Medium Flow, Grade 161, 4.7cm Diameter (Box of 100)

Ahlstrom 1610-0470 Borosilicate Glass Microfiber Filter Paper, 1.1 Micron, Medium Flow, Grade 161, 4.7cm Diameter (Box of 100) - Grade 161 is generally recommended for water pollution monitoring techniques for total suspended solids. Grade 161 is used in general laboratory applications, cell harvesting, liquid scintillation counting, and in the monitoring of air and water pollution. This popular grade offers finer particle retention and higher flow rate than traditional analytical filter papers. Offers a full range of glass microfiber filters manufactured from 100 percent pure borosilicate glass. Standard glass microfiber filters. It is also found in the filtration of hot gases and liquids, and in pre-filtration. Laboratory analysis, 100 percent pure borosilicate glass, rapid flow rate, high loading capacity, chemical and thermal resistance (up to 500 degree c), long shelf life, brilliant white color reflecting more than 96 percent of visible light, custom cut. Standard glass microfiber filters contain no binders or other additives that may cause interference to sensitive enzymatic or other chemical reactions. Microfiber filters include environmental analysis for water, wastewater, testing of soils, air pollution and monitoring, research and process biochemistry, and gravimetric analysis involving ignition of samples. Because of their intrinsic properties, glass microfiber filters have wide applications in many areas of laboratory analysis, especially when fine filtration and high loading capacity is required. The unique characteristics of glass microfiber filters make its use particularly advantageous to laboratory filtration by enabling fast filtration of large volumes and difficult solutions without premature clogging.

 

GVS Life Sciences 1225509 Borosilicate Glass Fiber Filters Disks without Binder 10 micron Pore Size 90mm Diameter Pack of 25

GVS Life Sciences 1225509 Borosilicate Glass Fiber Filters Disks without Binder, 1.0 micron Pore Size, 90mm Diameter (Pack of 25)

GVS Life Sciences 1225509 Borosilicate Glass Fiber Filters Disks without Binder, 1.0 micron Pore Size, 90mm Diameter (Pack of 25) - Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Frequency and cost of replacing the final membrane filters is reduced. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Not recommended for temperatures exceeding 510°c. Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Presep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids.

 

Thomas F1250-2 Borosilicate Glass Microfiber Filter 07 Micron Medium Flow Grade F 125cm Diameter Pack of 50

Thomas F1250-2 Borosilicate Glass Microfiber Filter, 0.7 Micron, Medium Flow, Grade F, 12.5cm Diameter (Pack of 50)

Thomas F1250-2 Borosilicate Glass Microfiber Filter, 0.7 Micron, Medium Flow, Grade F, 12.5cm Diameter (Pack of 50) - 80 grams per meter squared basis weight. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence of, if any, binder material that acts as a strengthening agent and aids in holding the fibers together. Fine porosity, medium flow rate, with a 0. The fibrous material within the filter is commonly glass micro fiber or polypropylene. May also be used for tclp analysis and collecting extremely fine precipitated proteins, including immunoglobulins. Depth filtration glass micro fiber. Binderless borosilicate glass microfiber. 7 micrometer size particle retention. Because of the characteristically high flow rates of depth filters, they are generally used in applications such as single and multi process removal of sediment and course particulate. Depth filtration categorizes filter media that traps particulate within the random matrix of fibers found within the thickness of the media. The efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. Frequently used with grade d to filter diluted aqueous solutions containing strong oxidizing, acidic, or alkaline components prior to laser spectroscopy. Glass micro fiber filters are available without binders, making the inertmatrix an ideal medium to entra-sediment for further analysis and counting. Also, depth filtration media is commonly used as pre-filtration prior to surface filtration substrates such as membranes.

 

Advantec GA5537MM GA55 Glass Fiber Filters 16 um 37 mm Dia 100Box

Advantec GA5537MM GA55 Glass Fiber Filters, 1.6 um, 37 mm Dia; 100/Box

Advantec GA5537MM GA55 Glass Fiber Filters, 1.6 um, 37 mm Dia; 100/Box - For analytical or gravimetric studies. Quartz fiber filters have very low trace metal content and can withstand up to 1832°f (1000°c). Choose quartz fiber filters to sample acidic gases at high temperatures or for air pollution analysis. Use as prefilters to extend membrane life, for water/air pollution analysis, or liquid clarification. Filters without binder withstand up to 932°f (500°c) filters with binder withstand up to 250°f (120°c). Borosilicate glass filters create a biologically inert filter matrix that is resistant to both chemicals and ph extremes. Grades gc90, gs25, and dp70 with binder offer higher wet strength and lower fiber release.

 

GVS Life Sciences 1215540 Borosilicate Glass Fiber Filters Disks without Binder 07 micron Pore Size 47mm Diameter Pack of 100

GVS Life Sciences 1215540 Borosilicate Glass Fiber Filters Disks without Binder, 0.7 micron Pore Size, 47mm Diameter (Pack of 100)

GVS Life Sciences 1215540 Borosilicate Glass Fiber Filters Disks without Binder, 0.7 micron Pore Size, 47mm Diameter (Pack of 100) - Presep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Frequency and cost of replacing the final membrane filters is reduced. Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Not recommended for temperatures exceeding 510°c.

 

Sterlitech - Grade F Borosilicate Glass Fiber Filter 07um Pore Size 47mm Diameter 100pk - F4700

Sterlitech – Grade F Borosilicate Glass Fiber Filter, 0.7um Pore Size, 47mm Diameter, 100/pk – F4700

Sterlitech – Grade F Borosilicate Glass Fiber Filter, 0.7um Pore Size, 47mm Diameter, 100/pk – F4700 - 7um size particle retention. Fine porosity, medium flow rate, with a 0. Use with diluted aqaueous solutions containing strong oxidizing, acidic, or alkaline components prior to laser spectroscopy.

 

Whatman 1825-125 Glass Microfiber Binder Free Filter 07 Micron 19 s100mL Flow Rate Grade GFF 125cm Diameter Pack of 25

Whatman 1825-125 Glass Microfiber Binder Free Filter, 0.7 Micron, 19 s/100mL Flow Rate, Grade GF/F, 12.5cm Diameter (Pack of 25)

Whatman 1825-125 Glass Microfiber Binder Free Filter, 0.7 Micron, 19 s/100mL Flow Rate, Grade GF/F, 12.5cm Diameter (Pack of 25) - It remains today the filter of choice. Unlike membrane filters with a comparable retention value, it has a very rapid flow rate with a high loading capacity. 7µm. Recommended for dna binding and purification. Retention 0. Whatman # 1825-125. 7µm. Gf/f filters are suitable for critical applications including enumeration of salmonella and pseudomonas aeroginosa, clarification of protein solutions and filtering samples and solvents prior to hplc. 8µm particle retention and pure borosilicate glass structure, gf/f is the material upon which the epa method tclp 1311 for toxicity characteristic leaching procedure was developed. 25/pack. 6µm-0. Very effective in filtering finely precipitated proteins, gf/f can be used in conjunction with gf/d as a prefilter for the successful clarification of difficult biochemical solutions and fluids, and nucleic acids. Because of the tight specification of 0. 5cm. Diameter 12. The whatman high efficiency gf/f filter will retain fine particles down to 0.

 

Corning FiltrEX 3511 Solid White Polystyrene 96 Well Filter Plate With 066mm Glass Fiber Filter Without Lid Case of 50

Corning FiltrEX 3511 Solid White Polystyrene 96 Well Filter Plate, With 0.66mm Glass Fiber Filter, Without Lid (Case of 50)

Corning FiltrEX 3511 Solid White Polystyrene 96 Well Filter Plate, With 0.66mm Glass Fiber Filter, Without Lid (Case of 50) - Non-sterile, solid white 96-well polystyrene filter plate has a 066mm (thickness) glass fiber filter and a 350l working volume. Nozzle design prevents cross-contamination while allowing the plate to rest on the lab bench lid not included. Individual filtrex filter discs are sealed in the wells by a patented over-molding process to ensure 100% integrity of each well. Rigid sidewalls make the plate ideal for automation handling, while the wide skirt easily accommodates bar codes.

 

Whatman 1820-047 Glass Microfiber Binder Free Filter 16 Micron 43 s100mL Flow Rate Grade GFA 47cm Diameter Pack of 100

Whatman 1820-047 Glass Microfiber Binder Free Filter, 1.6 Micron, 4.3 s/100mL Flow Rate, Grade GF/A, 4.7cm Diameter (Pack of 100)

Whatman 1820-047 Glass Microfiber Binder Free Filter, 1.6 Micron, 4.3 s/100mL Flow Rate, Grade GF/A, 4.7cm Diameter (Pack of 100) - Uses include water pollution monitoring of effluents, water filtration, algae and bacteria cultures, foodstuff analyses, protein filtration, radioimmunoassay of weak ß emitters. Diameter 47cm. Fine particle retention high flow rate good loading capacity used for high efficiency general purpose laboratory filtration. Grade gf/a retention 16µm. Recommended for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.

 

Millipore AP1507500 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis 10 Micron 16mLmin x sq cm Water Flow Rate AP15 75mm Diameter Pack of 100

Millipore AP1507500 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 1.0 Micron, 1.6mL/min x sq cm Water Flow Rate, AP15, 75mm Diameter (Pack of 100)

Millipore AP1507500 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 1.0 Micron, 1.6mL/min x sq cm Water Flow Rate, AP15, 75mm Diameter (Pack of 100) - No binder extractables. Highest dirt-handling capacity. Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents. Lowest dirt-holding capacity^recommended prefilter for 02 to 06m filters^filter code ap15 pore size (m) 10 thickness (m) 790^water flow rate, ml/min x cm squared 16 air resistance mm of h2o at 105 fpm or 53 cm/s 210 air flow liters/min/cm squared at 10 psi 106^dop penetration at 105 fpm (%) 010 protein binding (g/cm squared) 100 weight (g/m squared) 50.

 

Millipore AP2004700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis 20 Micron 13mLmin x sq cm Water Flow Rate AP20 47mm Diameter Pack of 100

Millipore AP2004700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 2.0 Micron, 1.3mL/min x sq cm Water Flow Rate, AP20, 47mm Diameter (Pack of 100)

Millipore AP2004700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 2.0 Micron, 1.3mL/min x sq cm Water Flow Rate, AP20, 47mm Diameter (Pack of 100) - Lower retention, higher dirt-holding capacity than ap15 filters^recommended prefilter for 08 to 80m filters use upstream to protect type ap15 filters^filter code ap20 pore size (m) 20 thickness (m) 380^water flow rate, ml/min x cm squared 13 air resistance mm of h2o at 105 fpm or 53 cm/s 48 air flow liters/min/cm squared at 10 psi 464^dop penetration at 105 fpm (%) 008 protein binding (g/cm squared) 60 weight (g/m squared) 59. Diameter (mm) 37. Diameter (cm) 37. Water flow (seconds) 23. Thickness (mm) 210.

 

Sterlitech - Grade TSS Borosilicate Glass Fiber Filter 15um 47 mm Diameter 100pk - TSS4700

Sterlitech – Grade TSS Borosilicate Glass Fiber Filter, 1.5um, 47 mm Diameter, 100/pk – TSS4700

Sterlitech – Grade TSS Borosilicate Glass Fiber Filter, 1.5um, 47 mm Diameter, 100/pk – TSS4700 - This material can tolerate temperatures up to 500 c and is applicable for determining suspended solids, total dissolved solids, and total solids. Features include fine porosity, fast flow rate, with a 1. Also widely used in cell harvesting applications and ria scintillation counting. 5um size particle retention. Equivalent to grade 934-ah material.

 

Ahlstrom 1610-1500 Borosilicate Glass Microfiber Filter Paper 11 Micron Medium Flow Grade 161 15cm Diameter Box of 100

Ahlstrom 1610-1500 Borosilicate Glass Microfiber Filter Paper, 1.1 Micron, Medium Flow, Grade 161, 15cm Diameter (Box of 100)

Ahlstrom 1610-1500 Borosilicate Glass Microfiber Filter Paper, 1.1 Micron, Medium Flow, Grade 161, 15cm Diameter (Box of 100) - Standard glass microfiber filters contain no binders or other additives that may cause interference to sensitive enzymatic or other chemical reactions. Laboratory analysis, 100 percent pure borosilicate glass, rapid flow rate, high loading capacity, chemical and thermal resistance (up to 500 degree c), long shelf life, brilliant white color reflecting more than 96 percent of visible light, custom cut. Standard glass microfiber filters. Offers a full range of glass microfiber filters manufactured from 100 percent pure borosilicate glass. The unique characteristics of glass microfiber filters make its use particularly advantageous to laboratory filtration by enabling fast filtration of large volumes and difficult solutions without premature clogging. Grade 161 is generally recommended for water pollution monitoring techniques for total suspended solids. Because of their intrinsic properties, glass microfiber filters have wide applications in many areas of laboratory analysis, especially when fine filtration and high loading capacity is required. It is also found in the filtration of hot gases and liquids, and in pre-filtration. Grade 161 is used in general laboratory applications, cell harvesting, liquid scintillation counting, and in the monitoring of air and water pollution. Microfiber filters include environmental analysis for water, wastewater, testing of soils, air pollution and monitoring, research and process biochemistry, and gravimetric analysis involving ignition of samples. This popular grade offers finer particle retention and higher flow rate than traditional analytical filter papers.

 

DSC - Grade TSS Borosilicate Glass Fiber Filter 15um 55 mm Diameter 100pk - TSS5500

DSC – Grade TSS Borosilicate Glass Fiber Filter, 1.5um, 55 mm Diameter, 100/pk – TSS5500

DSC – Grade TSS Borosilicate Glass Fiber Filter, 1.5um, 55 mm Diameter, 100/pk – TSS5500 - Equivalent to grade 934-ah material. Features include fine porosity, fast flow rate, with a 1. Also widely used in cell harvesting applications and ria scintillation counting. This material can tolerate temperatures up to 500 c and is applicable for determining suspended solids, total dissolved solids, and total solids. 5um size particle retention.

 

Millipore AP1504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis 10 Micron 16mLmin x sq cm Water Flow Rate AP15 47mm Diameter Pack of 100

Millipore AP1504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 1.0 Micron, 1.6mL/min x sq cm Water Flow Rate, AP15, 47mm Diameter (Pack of 100)

Millipore AP1504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 1.0 Micron, 1.6mL/min x sq cm Water Flow Rate, AP15, 47mm Diameter (Pack of 100) - Filtration device and accessory type filter discs/sheets. Filter color white. Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. Filter diameter, mm 47. Degree c filter type depth filter. Porosity % 90. Filter material glass fiber with binder resin. Filter surface plain. Wettability hydrophilic. Glass fiber filters are available with or without binder resins and can be sterilized by eo, gamma, or autoclave (121 degree c at 1 bar). They are also widely used for clarification of aqueous solutions. Millipore fibrous disc filters are available in a wide range of flow rates and throughput capacities.

 

Omicron 133047 Borosilicate Glass Fiber Binder Free Filter 12 μm 47 mm Pack of 100

Omicron 133047 Borosilicate Glass Fiber Binder Free Filter, 1.2 μm, 47 mm (Pack of 100)

Omicron 133047 Borosilicate Glass Fiber Binder Free Filter, 1.2 μm, 47 mm (Pack of 100) - 2μm, 47mm pack of 100. Binder free borosilicate glass fiber filter, 1.

 

GVS Life Sciences 1215577 Borosilicate Glass Fiber Filter Membrane with Binder 10 micron Pore Size 47mm Diameter Pack of 100

GVS Life Sciences 1215577 Borosilicate Glass Fiber Filter Membrane with Binder, 1.0 micron Pore Size, 47mm Diameter, (Pack of 100)

GVS Life Sciences 1215577 Borosilicate Glass Fiber Filter Membrane with Binder, 1.0 micron Pore Size, 47mm Diameter, (Pack of 100) - Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. 5 greater than g20. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. 0 μm (g25) glass fiber with binders thickness is approximately 3. Maximum operating temperature is 165°c (325°f). Protection of 0. 8 μm final filters and larger pore sizes. 1.

 

GE Whatman Reeve Angel 5925-090 TCLP Glass Fiber Filter Paper Circle 9cm Diameter Pack of 100

GE Whatman Reeve Angel 5925-090 TCLP Glass Fiber Filter Paper, Circle, 9cm Diameter (Pack of 100)

GE Whatman Reeve Angel 5925-090 TCLP Glass Fiber Filter Paper, Circle, 9cm Diameter (Pack of 100) - Diameter 19cm. Manufactured primarily for non-critical industrial laboratory filtration applications requiring inexpensive filters of consistent performance. Toxicity characteristic leaching procedure. This reeve angel borosilicate glass fiber filter paper conforms to epa method 1311, 5w-846.

 

Millipore AP2504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis 20 Micron 58mLmin x sq cm Water Flow Rate AP25 47mm Diameter Pack of 100

Millipore AP2504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 2.0 Micron, 5.8mL/min x sq cm Water Flow Rate, AP25, 47mm Diameter (Pack of 100)

Millipore AP2504700 Glass Fiber Filter with Binder Resin for Prefiltration and Contamination Analysis, 2.0 Micron, 5.8mL/min x sq cm Water Flow Rate, AP25, 47mm Diameter (Pack of 100) - Added thickness yields same retention and greater dirt-holding capacity as ap20^recommended prefilter for 09 to 8m filters, especially for proteinaceous and heavily contaminated liquids use upstream to protect type ap15 filters^filter code ap25 pore size (m) 20 thickness (m) 1200^water flow rate, ml/min x cm squared 58 air resistance mm of h2o at 105 fpm or 53 cm/s 35 air flow liters/min/cm squared at 10 psi 636^dop penetration at 105 fpm (%) 003 protein binding (g/cm squared) 110 weight (g/m squared) 140. 100% borosilicate glass microfiber, binder free. Thickness 025 mm. Standard for suspended solids content and related measurements (sm 2540d and epa method 1602).