24 Top Turbidity Meters for 2019

 

LaMotte 1970-ISO Model 2020wi Portable Turbidity Meter Kit Complies with ISO 7027 Standard

LaMotte 1970-ISO Model 2020wi Portable Turbidity Meter Kit Complies with ISO 7027 Standard

LaMotte 1970-ISO Model 2020wi Portable Turbidity Meter Kit Complies with ISO 7027 Standard - Lithium recharegeable batteries. Waterproof to ip67. Backlit display. Usb port. 7 languages.

 

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette 000 to 5000 FTU 001 FTU Resolution -05 FTU Accuracy

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette, 0.00 to 50.00 FTU, 0.01 FTU Resolution, +/-0.5 FTU Accuracy

Hanna Instruments HI93703 Portable Turbidity Meter with Cuvette, 0.00 to 50.00 FTU, 0.01 FTU Resolution, +/-0.5 FTU Accuracy - 00 ftu) 1 ftu (50 to 1000 ftu) resolution. 01 ftu (0. Both versions meet the requirements of glp (good laboratory practice) protocols for last calibration data storage. Microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements. 00 ftu 50 to 1000 ftu range. 3 points (0 ftu, 10 ftu and 500 ftu) calibration. 00 to 50. It is is supplied complete with glass cuvette, batteries and instructions. 5 ftu or +/-5 percent of reading (whichever is greater) accuracy. The hi 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and pc compatibility via the rs232 interface and windows compatible hi 92000 software. Infrared ledlight source. Hanna amco-aepa-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. 00 to 50. Hanna instruments has chosen 10 ftu as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. Hi 93703 can be used with both standards. Measures 8-11/16″ length by 3-3/16″ width by 2-19/32″ height. Silicon photocell light detection. Hi 93703 has been designed according to the iso 7027 international standard, consequently the turbidity unit is the ftu (formazine turbidity unit). +/-0. Formazine is a very toxic, unstable substance which requires particular care its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. Hanna instruments uses the primary standard amco-aepa-1 to avoid all formazine-related problems. Ftu is equivalent to the other internationally recognized unit ntu (nephelometric turbidity unit). It is easy to calibrate (with 3 point calibration) using amco-epa standards and is iso 7027 compliant.

 

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set For Turbidity Meter

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set, For Turbidity Meter

Hanna Instruments HI98703-11 4 Piece Calibration Cuvets Standard Set, For Turbidity Meter - Always handle the cuvet by touching only the cap or its top side (over the horizontal line). The 25 mm round cuvets made from special optical glass guarantee the repeatability and consistency of the measurements. Any cuvet with visible scratches will be discarded. The cuvets should be periodically washed with acid. The cuvets should be free of scratches or cracks.

 

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit

Hanna Instruments HI 93703C Portable Logging Turbidity Meter Kit - 5v aa batteries hi 93703-0 & hi 93703-10 cal. Solutions hi 93703-50 cleaning solution tissue for wiping cuvettes carrying case instructions. Hanna instruments manufactures a wide variety of analytical instrumentation, including ph meters, multi-parameter meters, electrodes, chemical reagents, and buffer solutions. Hanna instruments holds many firsts in the field of analytical instrumentation, including a ph electrode with a built-in temperature sensor, an electronic pocket-sized ph tester, and a replaceable electrode ph pocket tester. 5 ftu or 5% of reading, with a typical emc deviation of + or – 2% fs. Founded in 1978, hanna is headquartered in woonsocket, ri, with subsidiaries in 32 countries. ). The device operates on four 1. 2 x 2. To assure the quality of its products, hanna is a vertically integrated manufacturer and does not subcontract any part of its manufacturing. 7 x 3. 1 lb. Turbidity meters measure the loss of transparency due to suspended particles present in a solution. The meter has 3-point calibration (0, 10, and 500 ftu), uses an infrared led as a light source, and automatically shuts off after five minutes of non-use. What’s in the box two glass cuvettes with caps four 1. They are commonly used to measure the turbidity of water in both the field and laboratory. 6″), with weight 510 g (1. 00 formazine turbidity unit (ftu) and 50 to 1000 ftu, + or -. 00 to 50. The hanna instruments hi 93703c is a portable microprocessor-based turbidity meter. Dimensions are 220 x 82 x 66 mm (8. 5v aa batteries. Turbidity range is 0.

 

Oakton T100 T-100 Turbidity Meter handheld waterproof no standards

Oakton T100 T-100 Turbidity Meter, handheld, waterproof, no standards

Oakton T100 T-100 Turbidity Meter, handheld, waterproof, no standards - Power saving function lets you take over 1000 readings on a single set of aaa batteries. Other features include auto-off, diagnostic error messages, and auto-ranging function. No standards included in this package. Waterproof and dustproof with ip67-rated housing that floats meets performance criteria as specified by iso 7027 (din en 27027) method compliant with astm d6855-03 (epa recognized) four point push-button calibration for full-range accuracy auto-ranging from 0 to 1000 ntu. Sealed optical system with infrared light source delivers high accuracy across entire range. The large custom lcd displays reading and units of measure. Must order separately. What’s included three sample cuvettes, a light shield cap, 10-ml silicone oil, lint-free cloth, 4 aaa batteries, and hard carrying case. The oakton t-100 turbidity meter is easy to calibrate, meter automatically prompts you to the next calibration standard.

 

Extech TB400 Portable Turbidity Meter

Extech TB400 Portable Turbidity Meter

Extech TB400 Portable Turbidity Meter - Measures up to 1000 ntu (nephelometric turbidity unit) with 001 ntu resolution. Portable design allows you to take measurement on-site instead of bringing solution back to the lab. Microprocessor-based circuitry assures high accuracy and repeatable readings. Large big-digit lcd and splash-proof front panel. Requires only a 10ml sample size.

 

Milwaukee Mi415 Turbidity Meter 000 - 5000 FNU50 - 1000 FNU 0011 FNU Resolution

Milwaukee Mi415 Turbidity Meter, 0.00 – 50.00 FNU/50 – 1000 FNU, 0.01/1 FNU Resolution

Milwaukee Mi415 Turbidity Meter, 0.00 – 50.00 FNU/50 – 1000 FNU, 0.01/1 FNU Resolution - 00, 50. 00 fnu/50, 1000 fnu, 0. 01/1 fnu resolution offers accurate and reliable readings. Milwaukee mi415 turbidity meter, 0.

 

LaMotte 1451 Turbidity Standard EPA for 2020WETC3000WeLTC3000WE Turbidity Meter 10 NTU 60ml Volume

LaMotte 1451 Turbidity Standard (EPA) for 2020WE/TC3000We/LTC3000WE Turbidity Meter, 10 NTU, 60ml Volume

LaMotte 1451 Turbidity Standard (EPA) for 2020WE/TC3000We/LTC3000WE Turbidity Meter, 10 NTU, 60ml Volume - Odorless. Appearance clear, colorless solution.

 

Milwaukee Instruments Mi0011 Glass Cuvet for Mi415 Turbidity Meter Wine-Line Photometer and MW Series Handy Photometer Small 10 mL

Milwaukee Instruments Mi0011 Glass Cuvet for Mi415 Turbidity Meter, Wine-Line Photometer and MW Series Handy Photometer, Small, 10 mL

Milwaukee Instruments Mi0011 Glass Cuvet for Mi415 Turbidity Meter, Wine-Line Photometer and MW Series Handy Photometer, Small, 10 mL - Milwaukee instruments 10ml small glass cuvet for mi415 turbidity meter, wine-line photometer and mw series handy photometer.

 

Turbidity Meter Model TU-2016

Turbidity Meter Model TU-2016

Turbidity Meter Model TU-2016 - Accuracy 5 % fs or 05 ntu, whichever is greater. Power 15 v battery (um-4/aaa) x 6 pcs | 0 ntu and 100 ntu calibration solution are included. Range auto range (two ranges) 000 to 5000 ntu, 50 to 1,000 ntu. Resolution 001 ntu/1 ntu. Light source led, 850 nm | record max, min value.

 

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter Set of 6

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter (Set of 6)

LaMotte 0290-6 Glass Test Tube with Cap for 2020E Turbidity Meter (Set of 6) - 10ml volume capacity. Can be used for standards or water samples. White line ensures test tube is correctly aligned in the meter. Set of six glass test tubes with screw-on caps for use with lamotte 2020e turbidity meter and smart 3 colorimeter (meters not included).

 

LaMotte 1485 Turbidity Standard EPA for 2020ETC-3000E Turbidity Meter 10 NTU 60ml Volume

LaMotte 1485 Turbidity Standard (EPA) for 2020E/TC-3000E Turbidity Meter, 10 NTU, 60ml Volume

LaMotte 1485 Turbidity Standard (EPA) for 2020E/TC-3000E Turbidity Meter, 10 NTU, 60ml Volume - Lamotte 1485 turbidity standard (epa) for 2020e/tc-3000e turbidity meter, 10 ntu, 60ml volume.

 

Orion AQUAfast Turbidity Meter Kit

Orion AQUAfast Turbidity Meter Kit

Orion AQUAfast Turbidity Meter Kit - 99 ntu with 0. 01 ntu resolution, 20. 9 ntu with 0. Waterproof rating ip67. Display lcd. 0 to 99. Orion # aq3010. Response time 3000 tests and (4 x aaa lithium >12000 tests). Battery conservation feature auto shutoff after 20 minutes of inactivity. Ergonomic ip67 turbidity meter for lab or field use. Uses nephelometric principle with 90° detection. Meets iso 7027 and offers consistent light source for greater accuracy. Keys power, cal, scroll up, scroll down, read/enter. Automatic range selections and resolution 0. No mixing or diluting with epa approved polymer bead primary standards for faster calibration. Turbidity meter is perfect for plant, field or lab, this simple, yet powerful turbidity meter offers impressive features. Autoranging from 0 to 1000 ntus, the aq3010 meter generates an accurate turbidity reading in seconds. Precision +/-2% of reading +/-1 lsd for 0-500 ntu, +/-3% of reading +/-1 lsd for 501-1000 ntu. In many locations, a separate light cap or shield is not needed. Thermo orion aquafast turbidity meter kit. Ambient operating temperature 0 to 50°c (0 to 90% non-condensing relative humidity at 30°c ). 1 ntu resolution, 100-1000 ntu with 1 ntu resolution. 01 to 19.

 

Oakton T-100 Turbidity Meter Kit with Calibration Vials

Oakton T-100 Turbidity Meter Kit, with Calibration Vials

Oakton T-100 Turbidity Meter Kit, with Calibration Vials - Auto-ranging from 0 to 1000 nephelometric turbidity units (ntu) for ease of use. Large lcd graphic displays readings and measurements for ease of viewing. Waterproof, dustproof meter with ingress protection (ip) 67-rated housing that floats, if dropped. Power-saving function to take up to 1,200 readings for high functionality. Four-point, push-button calibration for full range accuracy.

 

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale 0 Degree C to 50 Degree C Temperature Range 52 mm Height 104 mm Width 192 mm Length

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale, 0 Degree C to 50 Degree C Temperature Range, 52 mm Height, 104 mm Width, 192 mm Length

Milwaukee Instruments Mi415 Turbidity Meter with FTU Scale, 0 Degree C to 50 Degree C Temperature Range, 52 mm Height, 104 mm Width, 192 mm Length - Mi415 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9v battery and instructions. By measuring turbidity, by photometric or tube methods, it is possible to estimate suspended solids content. For potable water applications turbidity is a good indicator of water quality. Turbidity measurement is achieved by analyzing the amount of light refracted from suspended particles such as clay, silt and organic material. 00 fnu, and 50 to 1000 fnu that can accommodate the most turbid condition you may encounter. Mi415 has two operating ranges 0. 00 to 50. Turbidity is a measure of the clarity of a sample. Turbidity refers to the concentration of undissolved, suspended particles present in a liquid.

 

LaMotte 1483 Turbidity Standard ISO for 2020ITC-3000I Turbidity Meter 100 NTU 60 mL Volume

LaMotte 1483 Turbidity Standard (ISO) for 2020I/TC-3000I Turbidity Meter, 100 NTU, 60 mL Volume

LaMotte 1483 Turbidity Standard (ISO) for 2020I/TC-3000I Turbidity Meter, 100 NTU, 60 mL Volume - Lamotte 1483 turbidity standard (iso) for 2020i/tc-3000i turbidity meter, 100 ntu, 60 ml volume.

 

WTW 600544 Cal KalStd P Turbidity Meter 10000NTU IR

WTW 600544 Cal. Kal.Std P Turbidity Meter, 10000NTU IR

WTW 600544 Cal. Kal.Std P Turbidity Meter, 10000NTU IR - White light has a higher sensitivity for small particles, however, the inherent coloration of the solution has a stronger disturbing effect in this case. The reduction of light intensity in this case leads to a more accurate result than a 90° nephelometric measurement. Therefore, lab meters for high values are equipped with several measuring options ratio modes calculate the final result from different measured angles. Nephelometric or transmittance measuring-the nephelometric measurement at 90° scattered light is advantageous for lower turbidity, whereas the transmission measurement at 180° is beneficial for medium to high turbidity values with increasing turbidity, restray and scattering effects between particles are growing bigger. The ir measurement is required by din iso, the white light measuring by us epa. For ratiometric measurements, there is no specific standard method to be followed rather, procedures are established by the application or industry.

 

Hanna Instruments HI 98703 Portable Turbidity Meter with Fast Tracker Technology EPA Compliant

Hanna Instruments HI 98703 Portable Turbidity Meter, with Fast Tracker Technology, EPA Compliant

Hanna Instruments HI 98703 Portable Turbidity Meter, with Fast Tracker Technology, EPA Compliant - Automatically compensates for variation in lamp intensity, minimizing need for frequent calibration. Logs up to 200 measurements until data can be downloaded to windows. Equipped with tag identification system for using with electronic tags in the field. Two, three, or four-point calibration to obtain results across a wide range. Exceeds the requirements of the usepa method 1801 for wastewater and standard method 2130 b for drinking water.

 

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter ISO 115V 001 01 1 FNU Resolution

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter, ISO, 115V, 0.01; 0.1; 1 FNU Resolution

Hanna Instruments HI88713-01 LCD Benchtop Turbidity Meter, ISO, 115V, 0.01; 0.1; 1 FNU Resolution - 0 to 99. 1 1 ebc, ntu non-ratio mode- 0. 1 1 ntu/0. 01 0. 0 to 99. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process. Data can be transferred to a pc via optional hi 920013 usb cable and hi 92000 windows compatible software. A two, three, four or five-point calibration can be performed using the supplied standards. 99 10. The hi 88713 turbidity bench meter meets and exceeds the requirements of the iso 7027 standard. 99 10. 00 to 9. 99 10. 1 1 ntu/0. 0 to 99. 1 1 fnu, fau mode- 0. 9 100 to 1000 ntu 0. 01 0. Accuracy at25 degree c fnu mode- +/-2 percent of reading plus stray light, fau mode- +/-10 percent of reading, ntu ratio mode- +/-2 percent of reading plus stray light/+/-5 percent of reading above 1000 ntu, ntu non-ratio mode- +/-2 percent of reading plus stray light. Hi 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. Up to 200 measurements can be stored in internal memory. Range fnu mode- 0. 01 0. 99 10. Calibration points can be modified when user prepared standards are used. 00 to 9. 9 100 to 4000 ntu 0. 01 0. 1 1 ebc. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected. 00 to 9. It also compensates for variations in intensity of the led, limiting the need for frequent calibration. 9 100 to 1000 fnu, fau mode- 10. 00 to 9. 0 to 99. The hi 88713 turbidity bench meter has complete glp (good laboratory practice) functions that allow traceability of the calibration conditions. 01 0. 0 to 99. 9 100 to 980 ebc, ntu non-ratio mode- 0. 9 100 to 245 ebc. 0 to 99. Comprehensive contextual help is available at a simple key press. The hi 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic lcd. Resolution fnu mode- 0. 00 to 9. 1 1 fau, ntu ratio mode- 0. 9 100 to 4000 fau, ntu ratio mode- 0. 99 10.

 

Apera Instruments TN400 Portable Turbidity Meter Large Colored TFT display with graphic and text guides Accuracy ±1

Apera Instruments TN400 Portable Turbidity Meter, Large Colored TFT display with graphic and text guides, Accuracy: ±1%

Apera Instruments TN400 Portable Turbidity Meter, Large Colored TFT display with graphic and text guides, Accuracy: ±1% - Ce certified and comes with a 2-year warranty. Usepa certified non-toxic, easy-to-use reagecon high-molecular polymer standard solutions. Large clear tft color screen (measurement mode, green in calibration) with intuitive graphic and text operation guides. Generates accurate, quick, & consistent turbidity test results.

 

LaMotte 1972-EPA LTC3000we Laboratory Turbidity and Chlorine Meter EPA 1801 for Turbidity EPA 3305 for Chlorine

LaMotte 1972-EPA LTC3000we Laboratory Turbidity and Chlorine Meter, EPA 180.1 for Turbidity, EPA 330.5 for Chlorine

LaMotte 1972-EPA LTC3000we Laboratory Turbidity and Chlorine Meter, EPA 180.1 for Turbidity, EPA 330.5 for Chlorine - 05 ntu. The free and total chlorine range is 0-10 ppm with a mdl of 0. The turbidity range is 0-4,000 ntu with a mdl of 0. The meter meets epa 180. Iso unit also available. 1 for turbidity and epa 330. 5 for chlorine. The new ltc3000 is a benchtop turbidity, chlorine and color meter with wide range and high accuracy. The meter can store 500 data points which can be downloaded to a computer, allows 7 different languages, and runs on rechargeable batteries or a usb computer/wall adapter. 03 ppm.

 

Portable Turbidity Meter High Accuracy 230V - HI98703-02 - EACH

Portable Turbidity Meter, High Accuracy, 230V – HI98703-02 – EACH

Portable Turbidity Meter, High Accuracy, 230V – HI98703-02 – EACH - Fast and reliable reading, highly accurate for measuring range of 0-14 ph, 01 ph resolution, measure & display ph result simultaneously with lcd display, reliable and quick reading. Wide use, it’s great for home and laboratory uses water, pools, aquariums, spas, hydroponics, food, wine and beer making and more. Ease of use, you just remove the protective cap and immerse the ph meter electrode in the solution and turn on the ph by “on / off” switch to be measured beats the heck out of trying to see the colors of a litmus strip. Package contents, 1 × liumy ph meter, 1 × user manual, 1 x 24-month warranty, 24 hours of customer service. Hanna instruments inc.

 

Sper Scientific 860040 Turbidity Meter

Sper Scientific 860040 Turbidity Meter

Sper Scientific 860040 Turbidity Meter - Turbidity meter- turbidity (undissolved solids) is an important measure of water quality in environmental testing, wastewater, petrochemical, beverage industry, and electroplating. Uses the highly accurate nephelometric method to meet iso 7027 standards. Comes ready to use in a hard, foam lined, carrying case with 0 ntu and 100 ntu calibration solutions, distilled water, cleaning cloth, instruction manual, and 6 aaa batteries. Dimensions 6½ x 3 x 2½” (165 x 75 x 65 mm) weight 11 oz (310 g). Features push-button automatic 3-point calibration, auto-ranging, and min-max recall. This compact, battery operated meter is easily portable for use in the field or lab.

 

Hanna Instruments HI731331N Spare Cuvette For Turbidity Meter Pack of 4

Hanna Instruments HI731331N Spare Cuvette, For Turbidity Meter (Pack of 4)

Hanna Instruments HI731331N Spare Cuvette, For Turbidity Meter (Pack of 4) - Turbidity meters (also called turbidimeters) determine the concentration of solids in a sample of liquid (usually water). The company, founded in 1978 and headquartered in woonsocket, ri, meets international organization for standardization (iso) standard 9001. Turbidity meters indirectly determine the concentration of these solids by measuring the light scattered by particles in the sample. The hanna instruments hi 731331n spare cuvette is made of glass. Turbidity meters are commonly used to test drinking water, environmental water, and water used for food and beverages for compliance with government standards. Hanna instruments manufactures analytical instrumentation and supplies, including ph meters, electrodes, chemical reagents, and buffer solutions. It is an accessory for use with the hanna instruments hi 98703 portable turbidity meter, which is used to test drinking water and ambient water to meet government standards, and to monitor water used in the manufacture of food and beverages. Turbidity is the cloudiness of a liquid caused by the presence of suspended solids (particles) that may include microorganisms, yeast, or sediment.