15 Best Assay Kits in 2020

 

10010303-96 - 3125-200 mgdl - Triglyceride Colorimetric Assay Kit Cayman Chemical Company - Each

10010303-96 – 3.125-200 mg/dl – Triglyceride Colorimetric Assay Kit, Cayman Chemical Company – Each

10010303-96 – 3.125-200 mg/dl – Triglyceride Colorimetric Assay Kit, Cayman Chemical Company – Each - The glycerol released is subsequently measured by a coupled enzymatic reaction system with a colorimetric readout at 540 nm. -Measure tg levels in plasma, serum, cell lysates, and tissue homogenates -assay 26 samples in triplicate and 40 samples in duplicate -incubation 15 minutes | read colorimetric at 530-550 nm the measurement of triglyceride levels, in conjunction with other lipid assays, are useful in the diagnosis of primary and secondary hyperlipoproteinemia, dyslipidemia, and triglyceridemia. A simple, reproducible, and sensitive tool for assaying triglycerides in plasma, serum, cell lysates, and tissue homogenate samples. The assay is initiated with the enzymatic hydrolysis of the triglycerides by lipase to produce glycerol and free fatty acids. Caymanâ€s triglyceride assay kit provides a simple, reproducible, and sensitive tool for assaying triglycerides in plasma, serum, cell lysates, and tissue homogenate samples.

 

Glutathione S-transferase Assay Kit DGST-100

Glutathione S-transferase Assay Kit (DGST-100)

Glutathione S-transferase Assay Kit (DGST-100) - 1. 5. Glutathione transferase (gst ec 2. The rate of increase in absorbance at 340 nm is directly proportional to the gst activity in the sample. Bioassay systems glutathione s-transferase assay kit is based on the gst enzyme reaction between gsh and the gst substrate, cdnb (1-chloro-2,4-dinitrobenzene). Gst protects cells against foreign compounds such as carcinogens and drugs by catalyzing the attachment of glutathione to the compounds electrophilic and/or hydrophobic sites. The gst catalyzed formation of gs-dnb produces a dinitrophenyl thioether which can be detected spectrophotometrically at 340 nm. 18) is a multifunctionalenzyme that plays an important role in cellular detoxification.

 

Urea Assay Kit II DUR2-100

Urea Assay Kit II (DUR2-100)

Urea Assay Kit II (DUR2-100) - Fast and sensitive linear detection range (20 μl sample) 1 mg/ml (017 mm) to 100 mg/ml (17 mm) urea in 96-well plate assay. Convenient the procedure involves adding a single working reagent, and reading the absorbance after 5 minutes room temperature assay no 37°c heater is needed. For quantitative enzymatic determination of urea. High-throughput homogeneous “mix-incubate-measure” type assay can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day.

 

PractiChromTM L-Lactate Assay Kit PLLC-25

PractiChromTM L-Lactate Assay Kit (PLLC-25)

PractiChromTM L-Lactate Assay Kit (PLLC-25) - Sensitive and accurate detection limit of 005 mm (45 ppm, 045 mg/dl) and linearity to 2 mm (178 ppm, 178 mg/dl) l-lactate. For quantitative determination of l-lactate (l-lactic acid) using the pico explorer handheld absorbance reader. Cost efficient no need for expensive plate readers. Convenient assay performed with portable pico explorer device.

 

Glucose Uptake Assay Kit EFGU-100

Glucose Uptake Assay Kit (EFGU-100)

Glucose Uptake Assay Kit (EFGU-100) - Safe no radioactive material is used. Sensitive and accurate detection limit of 01 µm and linearity up to 5 µm 2-dg6p. Determination of glucose uptake in whole cells and evaluation of effects of ligands or drugs on glucose transport. Simple and convenient can be automated as a medium throughput assay for glucose transport in cells.

 

BioVision -Glucosidase Activity Colorimetric Assay Kit K690-100

BioVision ?-Glucosidase Activity Colorimetric Assay Kit, K690-100

BioVision ?-Glucosidase Activity Colorimetric Assay Kit, K690-100 - 1-10 mu of -glucosidase activity in a variety of samples. In this disease, glycogen accumulates in the lysosomes, resulting in progressive muscle weakness, heart failure and other neurological symptoms. In the biotechnology industry, -glucosidase is used to produce glucose from intermediate breakdown products of starch hydrolysis generated by enzymes such as amylase. In biovisionï¾’s -glucosidase activity colorimetric assay kit, -glucosidase hydrolyzes the substrate mix to release the p-nitrophenol that can be measured colorimetrically (od = 410 nm). Pompe disease, one of the 12 known glycogen storage diseases, is an autosomal recessive metabolic disorder attributed to -glucosidase deficiency. This is an easy, quick and high-throughput capable kit that can measure 0. Highly sensitive -glucosidase activity assay detection method- absorbance (od 410 nm) applications- measurement of -glucosidase activity in biological samples- screening -glucosidase inhibitors -glucosidase breaks down -1,4 linked polysaccharides to glucose, which can be utilized as a source of energy.

 

Mannitol Assay Kit EMNT-100

Mannitol Assay Kit (EMNT-100)

Mannitol Assay Kit (EMNT-100) - Convenient the procedure involves adding a single working reagent, and reading the absorbance after 30 minutes room temperature assay no 37°c heater is needed. Fast and sensitive use of 20 μl sample linear detection range 0007 to 3 mm mannitol in 96-well plate assay. For quantitative determination of d-mannitol in biological, food, beverage and agriculture samples. High-throughput “add-mix-read” type assay can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day.

 

Glycolysis Assay Kit ECGL-100

Glycolysis Assay Kit (ECGL-100)

Glycolysis Assay Kit (ECGL-100) - Direct determination of l-lactate produced by glycolysis in cell samples screening of glycolysis inhibitors. High-throughput “add-mix-read” type assay can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Convenient the procedure involves adding a single working reagent, and reading the absorbance after 30 minutes room temperature assay no 37°c heater is needed. Fast and sensitive use of 5 µl sample linear detection range up to 10 mm l-lactate in 96-well plate assay.

 

Myeloperoxidase Assay Kit EMPO-100

Myeloperoxidase Assay Kit (EMPO-100)

Myeloperoxidase Assay Kit (EMPO-100) - Inflammation may also result when mpo oxidizes various substances such as phenols and anilines. Myeloperoxidase (mpo ec 1. The fluorescence intensity of this product, measured at &labdaex/em = 530/585 nm, is proportional to the total peroxidation activity in the sample. 2. The provided mpo inhibitor is used to suppress peroxidase activity due to mpo in order to differentiate other peroxidase activities that may be present in the samples. 2) is a peroxidase enzyme and can be found in neutrophil, monocytes, and some soft tissue macrophages. Mpo has an ability to use chloride as a cosubstrate with hydrogen peroxide to generate hypochlorous acid, a powerful antimicrobial agent produced by neutrophils. Bioassay systems enzyfluotm myeloperoxidase (mpo) assay kit is based on the mpo enzyme reaction with hydrogen peroxide (h2o2) which oxidizes the dye reagent to a highly fluorescent product. However, an excessive production of hypochlorous acid can lead to oxidative stress and tissues damage. Studies show that increased mpo levels may increase the risk of myocardial infarction and cardiovascular disease. 11.

 

BioVision Alkaline Phosphatase Activity Colorimetric Assay Kit K412-500

BioVision Alkaline Phosphatase Activity Colorimetric Assay Kit, K412-500

BioVision Alkaline Phosphatase Activity Colorimetric Assay Kit, K412-500 - Biovisionâs alkaline phosphatase assay kit is a highly sensitive, simple, direct and hts-ready colorimetric assay designed to measure alp activity in serum and biological samples. Alkaline phosphatase (alp) catalyzes the hydrolysis of phosphate esters in alkaline buffer and produces an organic radical and inorganic phosphate. Changes in alkaline phosphatase level and activity are associated with various disease states in the liver and bone. The kit can detect 10-250 µu alp in samples. It contains 10 substrate tablets providing convenience for multiple usages. Highly sensitive assay, hts detection method- absorbance (405 nm)species reactivity- mammalian applications- the kit can detect 10-250 µu alp in samples. The kit uses p-nitrophenyl phosphate (pnpp) as a phosphatase substrate which turns yellow (λmax= 405 nm) when dephosphorylated by alp.

 

99923-5X Firefly Luciferase Lysis Buffer 15 mL - Luciferase Assay Kits Biotium - Each

99923-5X Firefly Luciferase Lysis Buffer, 15 mL – Luciferase Assay Kits, Biotium – Each

99923-5X Firefly Luciferase Lysis Buffer, 15 mL – Luciferase Assay Kits, Biotium – Each - Lyophilized kits have assay buffers provided as lyophilized solids, for room temperature shipping and convenient storage. Biotium also offers catalog number atp-gloâ” bioluminometric cell viability assay (catalog number 89138-938). -Flash-type assays for single sample luminometers or luminescence plate readers with sample injection systems -steady-luc assay three hour luminescence half-life -lyophilized kits have assay buffers provided as lyophilized solids the firefly luciferase, renilla luciferase, and dual luciferase assays are flash-type assays for single sample luminometers or luminescence plate readers with sample injection systems. The steady-luc assay is a glow-type assay with a luminescence half-life of about 3 hours. Lyophilized kits have assay buffers provided as lyophilized solids, for room temperature shipping and convenient storage. The steady-luc assay is a glow-type assay with a luminescence half-life of about three hours. The firefly luciferase, renilla luciferase, and dual luciferase assays are flash-type assays for single sample luminometers or luminescence plate readers with sample injection systems. The steady-luc kit can be used with luminescence plate readers without sample injection systems or for high-throughput screening. The steady-luc kit can be used with luminescence plate readers without sample injection systems or for high-throughput screening.

 

Collagen Assay Kit ECOL-100

Collagen Assay Kit (ECOL-100)

Collagen Assay Kit (ECOL-100) - Fast and sensitive linear detection range (20µl sample) 2 µg/ml to 50 µg/ml collagen in 96-well plate assay. Collagen determination in biological and cosmetic products. Safe non-radioactive assay. Convenient and high-throughput “add-mix-read” type assay no wash and reagent transfer steps are involved can be readily automated for processing thousands of samples per day.

 

Malachite Green Phosphate Assay Kit POMG-25H

Malachite Green Phosphate Assay Kit (POMG-25H)

Malachite Green Phosphate Assay Kit (POMG-25H) - The malachite green phosphate assay kit is based on quantification of the green complex formed between malachite green, molybdate and free orthophosphate. Assays can be executed in tubes, cuvettes or multi-well plates. The assay is simple and fast, involving a single addition step for phosphate determination. The assays can be conveniently performed in 96- and 384-well plates for high-throughput screening of enzyme inhibitors. The rapid color formation from the reaction can be conveniently measured on a spectrophotometer (600, 660 nm) or on a plate reader. The non-radioactive colorimetric assay kits have been optimized to offer superior sensitivity and prolonged shelf life. This product is for research use only and is not intended for diagnostic purposes.

 

Fluorescent Acetaldehyde Assay Kit EFAC-100

Fluorescent Acetaldehyde Assay Kit (EFAC-100)

Fluorescent Acetaldehyde Assay Kit (EFAC-100) - Fast and sensitive linear detection range (50µl sample) 05 µm to 60 µm acetaldehyde in 96-well plate assay. Convenient homogeneous “mix-incubate-measure” type assay can be readily automated on hts liquid handling systems for processing thousands of samples per day. Acetaldehyde determination in biological and food/beverage samples. High-throughput the procedure involves adding a single working reagent, and reading the absorbance after 30 minutes room temperature assay no 37°c heater is needed.

 

Indole Assay Kit DIND-100

Indole Assay Kit (DIND-100)

Indole Assay Kit (DIND-100) - The indole test is commonly performed on bacteria to classify them on their ability to break down tryptophan to indole. The intensity of this colored compound is directly proportional to the indole in the sample. Indole is the primary product of tryptophan breakdown by tryptophanase. Bioassay systems indole assay kit is based on a modified version of ehlrich’s and kovac’s reagents, which reacts with indole to produce a colored compound at 565 nm.





We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.